Cisco N3K-C3132Q-40GE Nexus 3132Q, 32x QSFP+ 40G+ 4x SFP 1RU switch
36,000,000VND
Thông số kỹ thuật :
Description | Specification | |
Physical | – 1RU fixed form-factor switch
– 32 QSFP+ ports; each supports native 40 Gigabit Ethernet and 4 x 10 Gigabit Ethernet modes – 4 SFP+ ports – 2 redundant power supplies – 4 redundant (3+1) fans – Management, console, and USB flash-memory ports |
|
Performance | – 2.5-Tbps switching capacity
– Forwarding rate up to 1.4 bpps – Line-rate traffic throughput (both Layer 2 and 3) on all ports – Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
|
Hardware tables and scalability* | Number of MAC addresses | 288,000 |
Number of VLANS | 4096 | |
Number of spanning-tree instances | – RSTP: 512
– MSTP: 64 |
|
Number of ACL entries | – 4000 ingress
– 1000 egress |
|
Routing table | – 16,000 prefixes and 16,000 host entries* – 8000 multicast routes* |
|
Number of EtherChannels | 64 (with vPC) | |
Number of ports per EtherChannel | 16 | |
System memory | 4 GB | |
Buffer size | 12 MB shared | |
Log Flash | 2GB | |
Boot-flash memory | 4 GB | |
Power | Frequency | 50 to 60 Hz |
Power supply types | – AC (forward and reversed airflow)
– DC (forward and reversed airflow) |
|
Typical operating power | 210W | |
Maximum power | 340W | |
AC PSUs
– Input voltage – Frequency – Efficiency |
– 100 to 240 VAC
– 50 to 60 Hz – 89 to 91% at 220V |
|
DC PSUs
– Input voltage – Maximum current (PSU output – System input) – Efficiency |
– –40 to –-72 VDC
– 33A (400W unit) – 85 to 88% |
|
Power-supply efficiency | 89 to 91% at 220V | |
Typical heat dissipation | – 3132Q: 717 BTU/hr | |
Maximum heat dissipation | – 3132Q: 1160 BTU/hr | |
Cooling | – Forward and reversed airflow schemes
◦ Forward airflow: Port-side exhaust (air enters through fan tray and power supplies and exits through ports); supported with AC and DC power supplies ◦ Reversed airflow: Port-side intake (air enters through ports and exits through fan tray and power supplies); supported with AC power supply only – Redundant fans – Hot swappable (must swap within 1 minute) |
|
Sound | Measured sound power (maximum)
– Fan speed: 40% duty cycle – Fan speed: 70% duty cycle – Fan speed: 100% duty cycle |
– 66.1 dBA
– 70.6 dBA – 76.9 dBA |
Environment | Dimensions (height x width x depth) | 1.72 x 17.3 x 19.7 in. (4.4 x 43.9 x 50.5 cm) |
Weight | 21.5 lb (9.3 kg) | |
Operating temperature | 32 to 104°F (0 to 40°C) | |
Storage temperature | –40 to 158°F (–40 to 70°C) | |
Operating relative humidity | – 10 to 85% noncondensing
– Up to 5 days at maximum (85%) humidity – Recommend ASHRAE data center environment |
|
Storage relative humidity | 5 to 95% noncondensing | |
Altitude | 0 to 10,000 ft (0 to 3000m) |
Các loại module quang Cisco sử dụng cho switch cisco N3K-C3132Q-40GE:
Part Number | Description |
QSFP-100G-AOC (1m-30m) | QSFP 100-Gbps to QSFP 100-Gbps AOC: 1, 2, 3, 5, 7, 10, 15, 20, 25, and 30m |
QSFP-100G-CU (1m-5m) | QSFP 100-Gbps to QSFP 100-Gbps copper DAC: 1, 2, 3, and 5m |
QSFP-4SFP25G-CU (1m-5m) | QSFP 100-Gbps to 4 x SFP 25-Gbps passive copper breakout cable: 1, 2, 3, and 5m |
QSFP-100G-SR4-S | 100GBASE SR4 transceiver module with MPO-12 connector, multimode fiber up to 100m |
QSFP-100G-LR4-S | 100GBASE LR4 transceiver module for single-mode fiber (SMF) with LC connector, 10km |
QSFP-100G-CWDM4-S | 100GBASE CWDM4 transceiver module for single-mode fiber (SMF) with LC connector, 2km |
QSFP-100G-PSM4-S | 100GBASE PSM4 transceiver module with MPO-12 connector, single-mode fiber up to 500m |
Các loại nguồn sử dụng cho switch cisco N3K-C3132Q-40GE:
N2200-PAC-400W | N2K/3K 400W AC Power Supply, Forward airflow (port side exhaust) |
N2200-PAC-400W-B | N2K/3K 400W AC Power Supply, Reversed airflow (port side intake) |
N2200-PDC-400W | N2K/3K 400W DC Power Supply, Forward airflow (port side exhaust) |
N3K-PDC-350W-B | N3K Series 350W DC Power Supply, Reversed airflow (port side intake) |
Các loại Fan sử dụng cho switch cisco N3K-C3132Q-40GE:
N3K-C3064-FAN | Nexus 3064 Fan Module, Forward airflow (port side exhaust) |
N3K-C3064-FAN-B | Nexus 3064 Fan Module, Reversed airflow (port side intake) |
Đánh giá